Vitalograph In2itive hand-held Spirometer

In2itive

Vitalograph In2itive – combines the benefits of full spirometry, data integration and mobility in a small lightweight handheld spirometer.  Robust Fleisch flow measuring technology and a simple icon driven menu, plus a large, high resolution colour touch-screen and storage capacity for 10,000 subjects, makes In2itive the ideal solution for high quality spirometry on the move.

Manual entry of subject data is optional as In2itive makes it possible to select all subject data from Spirotrac and download it automatically “saving time and eliminating data entry errors. Utilising Spirotrac V, predicted values are available through integration of the clinical results” All Ages by Stanojevic

  • Features:
  • Cradle for battery charging, PC connectivity
  • Assured hygiene with removable flowhead
  • Hours of battery life for off-site testing
  • Over 50 test parameters

 

Product Name: In2itive Hand Held Spirometer

Part No: 2120

  • Subjects: Automatic population of database
  • from Spirotrac. Name, ID; Age, Height, Gender;
  • Smoking status, Body Mass Index and more
  • depending on model. Storage of up to 10,000 subjects
  • Environmental Data: Selectable: Temperature (built in sensors), Barometric pressure, altitude, humidity
  • Test types: Single breath tests, flow/volume loops, multi-breath testing, tidal breathing and combined VC/FVC type test methods supported
  • Selectable Parameters (depending on model):
  • VC; IVC; IC; VT (TV); TLC; RV; IRV; ERV; FRC; FVC; FIVC; FEV_; FEV_; FEV_; FVC; FEV_/VC; FEV_/FVC; FEV_/VC; FEV_/FVC; FEV_/FEV_; FEF__; FEF__; FEF__; FEF__-__; FEF__-__/FVC; FIV_; PIF, FIV_/FIVC, FIF__, FIF__, FIF__, FEF__/FIF__, FET, MVVind, FEV_ Ratio; FEV_._; PEF L/min; PEF L/s; FEF _._-_._; FEF 75-85%; FEF25%; FEF50%; FEF75%; FMFT; FIF25%; FIF50%; FIF75%; PIF; FEV_.__; Lung Age and more
  • Predicted Values Selectable (depending on model):
  • ERS/ECCS; NHANES, Polgar, Pereira, Berglund, Forsche, Gutierrez, Hedenstr_m, Taiwan; Knudson, Crapo; Hsu; KNLW; Viljanen; SEPAR; Gulsvik; SBPT; Tamura; Ip; Quanjer; Wang; Dockery and more
  • Suggested Interpretation: User selectable
  • Flow Technology: Fleisch Pneumotachograph (No3 size)
  • Resolution: 10 mL volume; 0.01 L/s flow
  • Data Storage: Stores up to 10,000 subjects and hundreds of test sessions
  • Accuracy when in Operating Range:
  • Volumes: Better than ± 3% (Max 10L / Min 0L); Flows: Better than ± 10% (Max 16L/s / Min 0.02L/s); Linearity: ± 5% in range 0.1 L/s to 16 L/s
  • PowerSAFE_: Input 100 – 240V AC 50-60Hz, output 5V DC
  • Battery Pack: Rechargeable Lithium Polymer 3.7v 2000mAH
  • Dimensions: Device: 160mm x 100mm x 45mm (with _owhead attached)
  • Nett Weight: Device: 230g
  • Gross Weight and Size (Packed):
  • Weight: 1.5kg, Packed Size: 213mm x 199mm x 158mm
  • Storage Humidity: 10% to 95%
  • Storage Temperature: 0C to 50C
  • Recommended Operating Temperature Range: 17 – 37C; Design Limits 10-40C
  • Ambient Humidity: 0% to 99%
  • Connectivity: USB 2
  • Max Test Duration: 20s FVC; 30s VC
  • Performance Standards: ISO 26782:2009; ISO 23747:2007; ATS/ERS 2005
  • Safety Standards: IEC 60601-1:2005
  • Medical Safety Standard: Medical Devices Directive 2007/47/EC
  • Designed & Manufactured Under: ISO 13485:2003, FDA 21CFR820, CMDR
  • 36020 3-L Precision Syringe
  • 28750 BVF_ Bacterial/Viral Filters (50)
  • 20242 SafeTway Mouthpieces (200)
  • 20980 Mini SafeTway Mouthpieces (50)
  • 20303 Disposable Noseclips (200)
  • 42084 Flow conditioning meshes (10)